摘要: 选坐落于广州的一幢1梯2户6层为特定的参照建筑,用JGJ 75—2003《夏热冬暖地区居住建筑节能设计标准》的方法,计算该建筑物外装饰材料的太阳能辐射吸收率ρ与建筑物空调年耗电量指数(ECFc)的关系。结果表明:ρ值越低,建筑物ECFc越低,越节能;当ρ≤0.65时,ECFc≤0.5,即该建筑符合JGJ 75—2003的节能设计;证明反射隔热涂料的基本要求之一就是要降低涂料的ρ值。测量涂料的太阳能总反射比(TSR)结果表明:使用铬铁黑、铬铁红等颜料,在中等深度颜色到深颜色范围内,涂料的TSR能够提高10%~20%,节约空调年耗电量10%左右。
关键词:
建筑节能,
空调年耗电指数,
反射隔热涂料,
太阳能辐射吸收率,
铬铁黑
Abstract: A building with 2-resident and 6-floor in Guangzhou city was chosen as reference. This article calculated and discussed the relationship between the absorptivity of solar radiation(ρ)of exterior wall decorated materials and annual cooling electricity consumption factor(ECFC) in accordance with JGJ75-2003 《Design standards for energy efficiency of residential buildings in hot summer and cold winter zone》. The results showed that the lower of ρ, the lower of ECFc, the referential building would save more cooling electricity each year. When ρ≤0. 65, the ECFc≤0. 5, the referential building met the demand of JGJ 75-2003. It was demonstrated that one of the basic demands of the solar heat reflective and insulation coating was the reduction of the value ρ of coatings. The total solar reflective radiance(TSR)was measured, from which it was known that when chro Mck or red pigments were uwh, with a range of mid-to-dark colors, the TSR of the coatings could increase by 10%~20%, indicating the annual cooling electricity consumption dropped about 10%.
Key words:
building energy-saving,
annual cooling electricity consumption index,
architectural reflective thermal insulation coating,
the absorptivity of solar radiation,
chromite black pigment
林惠赐, 杨文睿. 建筑外墙反射隔热涂料节能效率探讨[J]. 涂料工业, 2011, 41(12): 71-75.
Lin Huici, Yang Wenrui. Study on the Energy Efficient Buildings Painted with Solar Heat Reflection and Insulation Coating[J]. Paint & Coatings Industry, 2011, 41(12): 71-75.