Paint & Coatings Industry ›› 2017, Vol. 47 ›› Issue (7): 71-75.

Previous Articles     Next Articles

Selection and Evaluation of Corrosion Inhibitors Used in Oil and Water Mixture Pipelines

Hu Xuyan1, Liu Yingkun2   

  1. 1. Zhanjiang Branch of CNOoC Ltd., Zhanjiang, Guangdong 524000;2. Safetech Research Institute, Beijing 100083, China
  • Online:2017-07-01 Published:2019-05-31

油水混输管道用缓蚀剂的筛选与评价

胡徐彦,刘英坤   

  1. 1、中海石油(中国)有限公司湛江分公司,广东湛江 524000;2、安科工程技术研究院(北京)有限公司,北京 100083
  • 作者简介:胡徐彦(1973—),高级工程师,从事海上油气田生产管理和技术研究工作。

Abstract: The inhibition performance of the eight corrosion inhibitors used in oil and water mixture pipelines was evaluated by means of dynamic simulation method and electrochemistry via the dynamic high-temperature autoclave and electrochemical workstation. Thus, tree well-performed corrosion inhibitors were selected and optimized in terms of their dosages, and the inhibition mechanism was also discussed. The results revealed that the 6#,8# and2# inhibitors showed better inhibition performance which were satisfied the corrosion rate less than 0.076 mm/a. Taking the economic efficiency into account, the preferable dosage of corrosion inhibitor was 40 mg/L.

Key words: dynamic simulation, electrochemistry inhibitor inhibition mechanism

摘要: 针对某油田日益恶劣的腐蚀工况,利用高温高压釜和电化学工作站,通过动态模拟法和电化学测试法对 8 种油水混输管道用缓蚀剂进行了筛选和评价,研究了缓蚀剂在加注浓度为 50 mg / L时的缓蚀性能,对筛选出来的缓蚀率较高的 3 种缓蚀剂进行浓度优化,并探讨了缓蚀机理。 研究表明:在本实验条件下,6#、8#、2#3 种缓蚀剂均表现出了较好的缓蚀性能,满足腐蚀速率小于 0.076 mm/a的要求。 从经济方面考虑,加注浓度为 40 mg/L 能够满足要求。

关键词: 动态模拟, 电化学, 缓蚀剂, 缓蚀机理