Study on the Storage Stability and Water Resistant Performance of Fire Retardant Coatings

  • You Panli1 ,
  • 2 ,
  • Yao Yadong1 ,
  • Yin Guangfu1 ,
  • Yang Zhenhua1 ,
  • Cheng Xiaowe i1 ,
  • LiXie ji
Expand
  • 1. College of Materials Science & Engineering Sichuan University, Chengdu 610064; 2. Engineering Department of Xichang College, Sichuan Xichang, 615013

Online published: 2019-01-24

Abstract

Through the study of the causes for poor water resistance, flocculation and viscosity increase of the title fireretardant coatings after storage, it is found that the binder and fire retardant are thema in causes of the storage instability. Utilization of modified emulsion blend and microw ave radiated intumescent retardant will greatly improve the storage stability and the water resistant time increased from 12 h to 32 h, the flame retardant time increased from 23 min to 58 min.

Cite this article

You Panli1 , 2 , Yao Yadong1 , Yin Guangfu1 , Yang Zhenhua1 , Cheng Xiaowe i1 , LiXie ji . Study on the Storage Stability and Water Resistant Performance of Fire Retardant Coatings[J]. Paint & Coatings Industry, 2006 , 36(4) : 24 -27 . DOI: 10.12020/j.issn.0253-4312.2006.04.24